The analogue pulse converter AD-AI 200 GVC converts analogue signals to quantity signals, which, for instance, correspond to a flow or throughput. These pulses are outputted via the internal relay or, optionally, via a faster transistor. The AD-AI 200 GVC is equipped with a compact switching power supply, which works with high efficiency in a wide supply voltage range. The converter can be configured via the PC with an available parametric software AD-Studio. However, it can also be delivered preset.

  Application

Producing quantity signals from a current or voltage signal. The exact description of the function can be found in the document "Functionality AI200GVC.pdf". Practical example 1: Input: 0...20 mA corresponds to a flow of 1000 l/h Output: 1 pulse/l Practical example 2: Input: 0...10 V corresponds to a throughput of 10 kg/min Output: 10 pulses/kg

AD-ai-200-gvc-analog-impuls-umsetzer.jpg

  Business data

Order number
AD-AI 200 GVC relay output
AD-AI 200 GVCO transistor output

  Download

PDF

  Technical specifications

Input
Input current 0/4 ... 20 mA (Rin: 50 Ohm) resolution 10 Bit
Input voltage 0/2 ... 10 V (Rin: 100 kOhm) resolution 10 Bit
Relay output
Max. load AC 250 V / 2 A (cos phi = 1)
Max. load DC 50 V / 1 A (ohmic load)
Cycles AC- load 2 A (cos phi = 1): ca. 110000
Cycles DC- load 1 A (ohmic load): ca. 100000
Pulse duration 0,5 ... 5 s
Transistor output (optional)
Max. load DC 30V / 50mA
Pulse duration 0,05 ... 5 s (50% duty cycle at high frequency)
Supply
Voltage range 20 ... 253 V DC / 50 ... 253 V AC
Power consumption max. 1,5 W / 2,6 VA (50 Hz)
Accuracy
Accuracy < 0,2 %
Input (AD-Converter) ca. 0,1 % of full scale
Housing
Dimensions (WxHxD) 18x110x134 mm
Type of protection IP 20
Connection method detachable terminal clamp (2,5 mm flex wire / 4 mm one wire)
Bolting torque screw terminals 0,5 Nm
Weight 135 g
Manner of fastening DIN rail 35mm (EN 50022)
Environmental conditions
Ambient temperature 0 ... 50 C
Storage and transport -10 ... 70 C (no thawing)
EMC
Product family standard EN 61326
Emitted interference EN 55011, CISPR11 Cl. B
Electrical safety requirements
Product family standard EN 61010-1
Galvanic isolation, test voltages
Input / output 4 kV (1 min.)
Signal / supply unit 4 kV (1 min.)
Protection circuits
Input electrical surge protection
Power supply electrical surge and reverse current protection
Relay output no protection
Transistor output electrical surge protection

  Block and wiring diagram

AD-ai200gvc-anschlussbelegung.svg

  Dimensions

AD-gvc-masszeichnung.svg