Frequency Converter
AD-FM 250 GVC


back to products

  Description

The frequency measuring converter AD-FM 250 GVC supplies an initiator or a contact and transforms its impulse sequence to a proportional impressed analogue signal. The output signal is independent from the connected load up to a maximum value. Furthermore, this series of devices is equipped with a configuration interface AD-PC as standard, with which the input and output measuring signal can be freely programmed with the programming software AD-Studio. Input, output and the supply voltage are separated from each other galvanically with high isolation.

  Application

The main area of application is the through-flow measuring at water meters, further applications are energy consumption measuring etc.

AD-fm-250-gvc-frequenzmessumformer.jpg

  Specific characteristics

  • Inputs: arbitrary
  • Outputs: current and voltage
  • Programming via configuration software
  •   Business data

    catalog number AD-FM 250 GVC

      Download

    PDF

      Technical specifications

    Digital input
    Input NAMUR (EN 60947-5-6), reed contact, open-collector, 3-lead opto-transmitter or 24V active
    Input frequency min. 0 ... 1 mHz; max. 0 ... 10 kHz
    Frequency generator supply active: ca. 13,5V (max. 13mA); NAMUR:8V/8mA
    Contact debouncing activatable, pulse duration > 40 ms
    Output current
    Output range 0 ... 20 mA; 4 ... 20 mA
    Max. burden 500 Ohm
    Residual ripple <50 µAss
    Output voltage
    Output range 0 ... 10 V, 2 ... 10 V
    Min. burden 10 kOhm
    Residual ripple <20 µVss
    Accuracy
    Unit 0,3%
    Temperature influence <100 ppm / K
    Response time approx. 70 ms
    Supply
    Supply voltage 20 ... 253 V DC / 50 ... 253 V AC
    Max. power consumption 2 W / 3,6 VA
    Housing
    Dimensions (WxHxD) 18x110x134mm
    Type of protection IP 20
    Connection method detachable terminal clamp
    Manner of fastening DIN rail 35mm (EN 50022)
    Weight ca. 130 g
    Environmental conditions
    Ambient temperature 0 ... 50 °C
    Storage and transport -10 ... 70 °C (no thawing)
    EMC
    Product family standard EN 61326
    Emitted interference EN 55011, CISPR11 Cl. B
    Galvanic isolation, test voltages
    Input/output 2 kV RMS (1 min.)
    Signal/auxiliary voltage 3 kV RMS (1 min.)

      Block and wiring diagram

    AD-fm250gvc-blockbild.svg

      Dimensions

    AD-gvc-masszeichnung.svg