  Description

The thermostat distributer AD-THV 10 serves the temperature-dependent regulation of a circulation pump and, at the same time, supplies an electric heating rod to a maximum of 2000 Watt (for higher performance, an external power-relay can be mounted). With this simple regulating device, a small amount of water can be heated electrically and, on reaching a temperature limit, a circulation pump can be switched on to a maximum of 100 Watt. The small amount of water heated in this way is now pumped into a large buffer supply tank (i.e. water storage tank in the heating). Due to this simple loading pump principle, the buffer supply tank is completely heated through. The known layering in the storage tank (warm at the top cold at the bottom) is therefore significantly reduced. With permanent operation, the buffer supply tank can be brought to an even maximum temperature. The AD-THV 10 requires a PT1000 resistance sensor for the temperature measuring, which is contained in the package. The switch point of the pump relay can be adjusted via an internal potentiometer. The switching hysteresis is permanently set.

  Application

Complete through stratification of water reservoirs on the charge pump principle. Works best in conjunction with the flow heater set AD-DLE.

AD-thv-10-thermostat-verteiler.jpg

  Specific characteristics

  • Simple thermostat function for controlling a pump
  • Adjustable switching threshold by potentiometer
  • Fixed hysteresis
  • No external wiring required
  • Control of pumps up to 100 Watt
  • IP65 casing
  •   Business data

    catalog number AD-THV 10

      Download

    PDF

      Technical specifications

    Sensor input
    Type PT1000
    Feeding voltage 5 V DC
    Measuring range 0 ... 150 C
    Output electric heater
    Max. power 2000 W (higher performance via external relay possible)
    Supply voltage 230 V AC +/- 10 %
    Output pump
    Max. power 100 W
    Supply voltage 230 V AC +/- 10 %
    Relay
    Contact construction closing contact
    Switching operations mechanical 1 000 000
    At 230V/2A AC, cos(phi)=1 600 000
    At 230V/2A AC, cos(phi)=0,4 200 000
    Supply
    Voltage range AC 230 V AC +/- 10 %
    Nominal voltage AC 230 V AC / 50 ... 60 Hz
    Power consumption AC / DC max. 2,3 VA
    Transmission behaviour
    Basic accuracy +/- 1 C
    Temperature influence 100 ppm/K
    Response time ca. 500 ms
    Switching hysteresis ca. 3 C
    Housing
    Dimensions (WxHxD) 160x140x80 mm
    Type of protection IP 65
    Connection method screw clamp
    Terminals, wire cross section 2,5 mm flex wire / 4 mm one wire
    Bolting torque terminals 0,5 Nm
    Weight ~ 510 g
    Manner of fastening wall housing
    Environmental conditions
    Ambient temperature 0 ... 50 C
    Storage and transport -10 ... 70 C (no thawing)
    EMC
    Product family standard EN 61326 1)
    Emitted interference EN 55011, CISPR11 Cl. B
    Electrical safety requirements
    Product family standard EN 61010-1
    Overvoltage category II
    Pollution degree 2
    Galvanic isolation, test voltages
    Power supply / sensor 4 kV, 50 Hz (1 min.)
    Protection circuits
    Temperature input electrical surge protection
    Pump output spark quenching
    Power supply Protection against overvoltage and overcurrent
    1) During checking, slight signal deviations are possible.

      Block and wiring diagram

    AD-thv10-blockbild_en.svg

      Dimensions

    AD-thv10-masszeichnung.svg

      Circuit examples

    AD-aufbauschema dle_de.svg