The digital multi-function measuring transformer of series VarioCheck AD-VC3B are freely programmable digital measuring transformer with two analogue outputs and up to 4 limiting value relays. Extensive standard equipment and additional options solve almost all imaginable tasks of a modern evaluation. The input of all characteristics is carried out via the configuration software „AD-Studio“. VarioCheck AD-VC3B fulfils all tasks of a universal and secure measuring value recording through integral function modules such as limiting value messages, freely adjustable hysteresis, selectable relay functions, time-delayed switching, automatic or manual simulation modus, free linearizing curves and a wide range of supply voltage.

AD-vc-3b-multi-messumformer.jpg

  Specific characteristics

  • Bipolar voltage/current inputs
  • Supply of 2-/3-wire transmitter
  • Potentiometer input
  • Current and voltage output, differently scalable and can be utilised simultaneously
  • Zoom function, expanded scale, linearizing, inverse modus
  • Monitoring of the measuring signal with up to 4 freely adjustable limiting values
  • Non-volatile saving of all set parameter
  • Pluggable and codable terminal strips
  • Parameter configuration via optional PC setup program "AD-Studio"
  •   Business data

    Order number
    AD-VC3B GVC-R0 without relay
    AD-VC3B GVF-R2 two relays
    AD-VC3B GVF-R4 four relays

      Download

    PDF

      Technical specifications

    Input current
    Measuring range -20 ... + 20 mA
    Accuracy 5 µA
    Input resistance 60 Ohm
    Voltage input 10V
    Measuring range -10 ... + 10 V
    Accuracy 2,5 mV
    Input resistance 1 MOhm
    Voltage input 1V
    Measuring range -1 ... + 1 V
    Accuracy 250 µV
    Input resistance > 1 MOhm
    Potentiometer input
    Connection method 3-wire system
    Max. Resistance 100 Ohm ... 100 kOhm
    Transmitter supply
    Off-load voltage 24,5 V
    Voltage at 20mA 19,5 V
    Current limit ~ 25 mA
    Output current
    Max. output range 0 ... 20,4 mA
    Accuracy ~ 20 µA
    Max. burden 500 Ohm
    Residual ripple 20 µAss
    Output voltage
    Max. output range 0 ... 10,2 V
    Accuracy ~ 10 mV
    Min. burden 5 kOhm
    Residual ripple 10 mVss
    Resolution
    Input 13 bit
    Output 10 bit
    Relay outputs A...D
    Contacts GVF-R2 / GVF-R4 2 changeover contact / 4 changeover contact
    Max. AC-breaking capacity 250 V AC, 2 A AC, 50Hz
    Max. DC-breaking capacity 35 V DC, 2 A DC
    Switching operations
    Mechanical 107
    AC: 230V / 2A, cos(phi)=1 6 * 105
    AC: 230V / 2A, cos(phi)=0,4 2 * 105
    DC: 24V / 1A 2 * 105
    DC: 24V / 1A 2 * 105
    Transmission behaviour
    Linearity error 0,2 % of full scale
    Rise time 100 ms (output auf 90 %)
    Temperature influence +/- 100 ppm/K of full scale
    Supply
    Supply voltage 20 ... 253 V DC / 50 ... 253 V AC
    Max. power consumption 2,6 W / 5 VAC
    Housing
    Manner of fastening DIN rail 35mm (EN 50022)
    Type of protection IP 20
    Connector cross section max. 2,5 mm˛
    Weight ~ 200 g
    Environmental conditions
    Ambient temperature -10 ... 60 °C
    Storage and transport -10 ... 70 °C (no thawing)
    EMC
    Product family standard EN 61326
    Discharge static electricity, ESD IEC 61000-4-2
    Electromagnetic fields 1) IEC 61000-4-3
    Fast transients, burst IEC 61000-4-4
    Impulse voltage, surge IEC 61000-4-5
    Conducted HF-Signals 1) IEC 61000-4-6
    Emitted interference EN 55011, CISPR11 Cl. B
    1)During electromagnetic disturbance minor changes in output signal are possible.
    Galvanic isolation, test voltages
    Input/output 2,5 kV (1 min)
    Signal/auxiliary voltage 4 kV (1 min)

      Block and wiring diagram

    AD-vc3_blockbild_en.svg

      Dimensions