AD-MWT 50 ST

Description

The transmitter AD-MWT 50 ST converts a Pt 100 temperature sensor signal into a passive transmitter signal (current sink: 4-20mA). An external supply voltage is not necessary. The necessary energy is taken from the transmitter supply at the output of the device. The impressed output signal corresponds to the desired input temperature range.

AD-MWT 50 ST

Application

Inexpensive conversion of a Pt 100 temperature transmitter signal into a passive impressed 4-20mA signal (2-wire transmitter technology)

Specific characteristics

  • 2-wire transmitter technology, low wiring effort
  • highly linear conversion, no adjustment due to 3-wire technology
  • supply voltage independent output signal of 4-20 mA
  • user-friendly plug-in design on terminal block

Business data

Order number
AD-MWT 50 ST
Identifiers
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Downloads
Data sheet pdf en-mwt50st.pdf (127 kB)
Safety instructions pdf ad-safety-instructions.pdf (43 kB)

Technical specifications

PT100-input
Measuring range Customer specification
Type PT100 3-wire system DIN IEC 751
Wiring 3-wire
Output current
Output range 4 ... 20 mA
Type Current sink
Residual ripple 30 µAss
Supply voltage drift Kein (betw. 8 ... 32 V)
Supply
Voltage range DC 8 ... 32 V DC
Nominal voltage DC 24 V DC
Power consumption DC Max. 0,65 W
Transmission behaviour
Basic accuracy < 0,2 %
Temperature influence 100 ppm/K
Response time ~ 20 ms
Housing
Dimensions (WxHxD) 20,8x42x102 mm
Type of protection IP 20
Connection method Screw terminals in plug-in socket
Terminals, wire cross section 2,5 mm² flex wire / 4 mm² one wire
Bolting torque terminals 0,5 Nm
Weight ~ 100 g
Manner of fastening 35 mm DIN rail 35mmPlug-in socket
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard EN 61326-1 1)
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Elevation Max. 2000 m
Pollution degree 2
Protection circuits
Input Electrical surge protection
Output Electrical surge protection
1) During checking, slight signal deviations are possible.

Block and wiring diagram

AD-MWT 50 ST

Dimensions

AD-MWT 50 ST

CAD / CAE Daten

CAD model is not yet available for this product.

The CAD product overview can be found at: adamczewski.partcommunity.com