AD-TV 300 GS

Description

The universal isolating amplifier AD-TV 300 GS converts the three standard industrial signals 0...20 mA, 4...20 mA and 0...10 V, amplifies them and separates them galvanically. The three signals are also available at the output. All combinations are possible. A switchover is not necessary. The signal combination from input to output is selected via the terminals.

AD-TV 300 GS

Application

Amplification and adaptation of standard signals with easy conversion to a freely selectable output signal.

Specific characteristics

  • Three standard signals freely selectable at the input and output
  • Galvanic isolation and amplification
  • No mechanical switches necessary
  • Input / output combination by clamping the desired signals
  • No subsequent adjustment necessary
  • Suppression of live zero signal (4mA)
  • Price / performance ratio allows for warehousing

Business data

Order number
AD-TV 300 GS
Identifiers
EClass 27210120
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Downloads
Data sheet pdf en-tv300.pdf (210 kB)
Safety instructions pdf ad-safety-instructions.pdf (43 kB)

Technical specifications

Current inputs
Measuring range 1 0 ... 20 mA
Measuring range 2 4 ... 20 mA
Input resistance 1/2 50 Ohm
Input voltage
Measuring range 0 ... 10 V
Input resistance 750 kOhm
Current outputs
Output range 1 0 ... 20 mA
Output range 2 4 ... 20 mA
Maximum burden 1/2 500 Ohm
Simultaneous use Nein
Output voltage
Output range 0 ... 10 V
Min. burden 1000 Ohm
Supply
Voltage range 50 ... 253 V AC (50 Hz),
20 ... 253 V DC
Nominal voltage 230 V AC (50 Hz), 24 V DC
Power consumption 4 VA, 2 W
Transmission behaviour
Basic accuracy < 0,2 %
Temperature influence 100 ppm/K
Response time ~ 50 ms (10...90 % output signal)
Housing
Dimensions (WxHxD) 18x78x103 mm
Type of protection IP 20
Connection method Screw clamp
Terminals, wire cross section 2,5 mm² flex wire / 4 mm² one wire
Bolting torque terminals 0,5 Nm
Weight ~ 140 g
Manner of fastening 35 mm DIN rail 35mm
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard EN 61326-1 1)
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Pollution degree 2
Galvanic isolation, test voltages
Input to output 3,75 kV, 50 Hz (1 min.)
Input, output to supply 3 kV, 50 Hz (1 min.)
1) During checking, slight signal deviations are possible.

Block and wiring diagram

AD-TV 300 GS

Dimensions

AD-TV 300 GS

CAD / CAE Daten

Under "Generate CAD", select the desired CAD model for this product.
For this purpose, registration with our CAD database "PARTcommunity" is required.
The complete CAD product overview can be found at: adamczewski.partcommunity.com

AD-TV 300 GS

Cookie settings
made with ♡ by andres.media