Kommunikation |
Frequency |
115,2 kHz |
Modulationsart |
AM |
Sendepegel |
Max. 122 dBµV |
Fehlersicherheit |
CRC + Handshake (bidirektional) |
Ausfallüberbrückung |
~ 8 Sekunden |
Norm |
EN50065-1 |
Supply |
Voltage range |
230 V AC (+/- 10 %), 50/60 Hz |
Nominal voltage |
230 V AC |
Power consumption |
2,3 VA |
Load-relay |
Maximale Schaltlast |
250 V AC, 9 A |
Contact construction |
Schließer (ein Kontakt) |
Switching operations mechanical |
6000000 |
At 230V/9A AC, cos(phi)=1 |
400000 |
At 230V/9A AC, cos(phi)=0,4 |
150000 |
Housing |
Dimensions (WxHxD) |
35,5 x 90 x 58 mm |
Type of protection |
IP 20 |
Connection method |
Screw clamp |
Terminals, wire cross section |
2,5 mm² flex wire / 4 mm² one wire |
Bolting torque terminals |
0,6 Nm |
Skinning length |
6 mm |
Weight |
~ 180 g |
Manner of fastening |
35 mm DIN rail 35mm |
Environmental conditions |
Ambient temperature |
-10 ... 50 °C |
Storage and transport |
-10 ... 70 °C (no condensation) |
EMC |
Product family standard |
EN 61326-1 1) |
Emitted interference |
EN 55011, CISPR11 Cl. B, Gr. 1 |
Electrical safety requirements |
Product family standard |
EN 61010-1 |
Overvoltage category |
II |
Pollution degree |
2 |
Schutzklasse |
II |
Protection circuits |
Power supply |
Protection against over-temperature, over-voltage and over-current |
|
1)During checking, communication errors are possible. |