Two channel bus to analog signal converter
|
-
|
Analog standard signal output
|
24V DC
|
GX
|
|
|
External input terminal block for LMB indicator lights with 12 inputs
|
12 logical signal inputs
|
-
|
Wide range power supply
|
WG
|
|
|
External input terminal block for LMB indicator lights with 24 inputs
|
24 logical signal inputs
|
-
|
Wide range power supply
|
WG
|
|
|
External input terminal block for LMB indicator lights with 32 inputs
|
32 logical signal inputs
|
-
|
Wide range power supply
|
WG
|
|
|
Two channel analog signal to bus converter
|
Analog standard signal input
|
-
|
24V DC
|
GX
|
|
|
Analog signal to bus converter
|
Analog standard signal input
|
-
|
Wide range power supply
|
GT
|
|
|
Analog signal to pulse converter
|
Analog standard signal input
|
Relay
|
Wide range power supply
|
GVC
|
|
|
Analog signal to pulse converter
|
Analog standard signal input
|
Solid state output
|
Wide range power supply
|
GVC
|
|
|
Isolation amplifier with analog memory function
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Surge protection for signal lines - Rough protection without series current limitation
|
2 wires
|
2 wires and protective earth
|
-
|
ST
|
|
|
Surge protection for signal lines - Rough and fine protection without series current limitation by resistors
|
2 wires
|
2 wires and protective earth
|
-
|
ST
|
|
|
Surge protection for signal lines - Rough and fine protection without series current limitation by iductances
|
2 wires
|
2 wires and protective earth
|
-
|
ST
|
|
|
Surge protection for signal lines - Rough and fine protection with cross-voltage limiting and longitudinal current limiting by resistors
|
2 wires
|
2 wires and protective earth
|
-
|
ST
|
|
|
Surge protection for signal lines - Rough and fine protection with cross-voltage limiting and longitudinal current limiting by inductances
|
2 wires
|
2 wires and protective earth
|
-
|
ST
|
|
|
Load amplifier for current standard signals
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Electrode relay
|
Electrodes
|
Relay
|
Wide range power supply
|
GS
|
|
|
Analog frequency transducer
|
Frequency or pulse input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
No longer available
|
|
Digital Frequency Transducer
|
Frequency or pulse input
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Digital Frequency Transducer with VarioControl interface, analog standard signal outputs and relays
|
Frequency or pulse input
|
Analog standard signal output, relay
|
Wide range power supply
|
GVD
|
|
|
Digital Frequency Transducer with VarioControl interface, analog standard signal outputs and solid-state output
|
Frequency or pulse input
|
Analog standard signal output, relay
|
Wide range power supply
|
GVD
|
|
|
Digital frequency transducer for front panel mounting 1-channel
|
Frequency or pulse input
|
Analog standard signal output and relay
|
Wide range power supply
|
FE
|
|
|
Digital frequency transducer for front panel mounting 1-channel
|
Frequency or pulse input
|
Analog standard signal output and semiconductor output
|
Wide range power supply
|
FE
|
Obsolescent model
|
|
Digital frequency transducer 1-channel
|
Frequency or pulse input
|
Analog standard signal output and relay
|
Wide range power supply
|
GA
|
Obsolescent model
|
|
Digital frequency transducer 1-channel
|
Frequency or pulse input
|
Analog standard signal output and solid-state output
|
Wide range power supply
|
GA
|
|
|
Digital frequency transducer 1-channel with RS485 interface
|
Frequency or pulse input
|
Analog standard signal output and relay
|
Wide range power supply
|
GT
|
|
|
Digital frequency transducer 1-channel with RS485 interface
|
Frequency or pulse input
|
Analog standard signal output and solid-state output
|
Wide range power supply
|
GT
|
|
|
Digital frequency transducer for front panel mounting 2-channel
|
Frequency or pulse input
|
Analog standard signal output and relay
|
Wide range power supply
|
FE
|
|
|
Digital frequency transducer for front panel mounting 2-channel
|
Frequency or pulse input
|
Analog standard signal output and semiconductor output
|
Wide range power supply
|
FE
|
Obsolescent model
|
|
Digital frequency transducer 2-channel
|
Frequency or pulse input
|
Analog standard signal output and relay
|
Wide range power supply
|
GA
|
Obsolescent model
|
|
Digital frequency transducer 2-channel
|
Frequency or pulse input
|
Analog standard signal output and solid-state output
|
Wide range power supply
|
GA
|
News
|
|
Digital frequency transducer 2-channel
|
Frequency or pulse input
|
Analog standard signal output and relay
|
Wide range power supply
|
GT
|
News
|
|
Digital frequency transducer 2-channel
|
Frequency or pulse input
|
Analog standard signal output and solid-state output
|
Wide range power supply
|
GT
|
|
|
DIN rail connector for GX device series, for wiring e.g. supply or bus signals.
|
-
|
-
|
-
|
SO
|
|
|
Clip on current transformers 100A for mounting on the DIN rail.. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
WG
|
|
|
Clip on current transformers 200A for mounting on the DIN rail.. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
WG
|
|
|
Clip on current transformers 50Afor mounting on the DIN rail.. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
WG
|
|
|
Electric heating element with 3.5 kW and three heating coils (500W, 1000W and 2000W)
|
-
|
-
|
3x 230V AC
|
SO
|
|
|
Pulse summer 2-channel with relay output
|
Pulse input
|
Relay
|
Wide range power supply
|
GVC
|
|
|
Pulse summer 2-channel with solid-state output
|
Pulse input
|
solid state output
|
Wide range power supply
|
GVC
|
|
|
Pulse summer 6-channel with relay output
|
Pulse input
|
Relay
|
Wide range power supply
|
GVF
|
|
|
Pulse summer 6-channel with solid-state output
|
Pulse input
|
solid state output
|
Wide range power supply
|
GVF
|
|
|
Incremental setpoint generator
|
Pulse input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Pulse reducer with relay output
|
Pulse input
|
Relay
|
Wide range power supply
|
GVC
|
|
|
Pulse reducer with solid-state output
|
Pulse input
|
solid state output
|
Wide range power supply
|
GVC
|
|
|
Bus to relay converter 1-channel
|
-
|
Relay
|
24V DC
|
GX
|
|
|
Bus to relay converter 4-channel
|
-
|
Relay
|
Wide range power supply
|
GT
|
|
|
Bus to relay converter 8-channel
|
-
|
Relay
|
Wide range power supply
|
GT
|
|
|
Two channel digital input to bus converter
|
Analog standard signal input
|
-
|
24V DC
|
GX
|
|
|
Contact protection pulse relay
|
Frequency or pulse input
|
Relay
|
24V DC
|
GX
|
|
|
Contact protection pulse relay
|
Frequency or pulse input
|
Relay
|
Wide range power supply
|
GS
|
|
|
Contact protection pulse relay
|
Frequency or pulse input
|
solid state output
|
Wide range power supply
|
GS
|
|
|
Coupling relay 1 changeover
|
Pulse input
|
Relay
|
24V DC
|
GX
|
|
|
Coupling relay 2 NO
|
Pulse input
|
Relay
|
24V DC
|
GX
|
|
|
Coupling relay 2 channel
|
Pulse input
|
Relay
|
24V DC
|
GX
|
|
|
Clip on current transformers 100A. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
SO
|
|
|
Clip on current transformers 200A. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
SO
|
|
|
Clip on current transformers 400A. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
SO
|
|
|
Clip on current transformers 5A. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
WG
|
|
|
Clip on current transformers 50A. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
SO
|
|
|
Clip on current transformers 600A. For use with Adamczewski power transmitters.
|
AC currents
|
AC mA currents
|
-
|
SO
|
|
|
Contact amplifier
|
Pulse input
|
Relay
|
Wide range power supply
|
GS
|
|
|
Contact amplifier
|
Pulse input
|
solid state output
|
Wide range power supply
|
GS
|
|
|
EX contact amplifier 1-channel with relay output
|
Pulse input (Exi)
|
Relay
|
Wide range power supply
|
GVD
|
|
|
EX contact amplifier 1-channel with solid-state output
|
Pulse input (Exi)
|
solid state output
|
Wide range power supply
|
GVD
|
|
|
EX contact amplifier 2-channel with relay output
|
Pulse input (Exi)
|
Relay
|
Wide range power supply
|
GVD
|
|
|
EX contact amplifier 2-channel with solid-state output
|
Pulse input (Exi)
|
solid state output
|
Wide range power supply
|
GVD
|
|
|
Indicator lights 6 LEDs
|
6 logical signal inputs
|
-
|
24V DC
|
FE
|
|
|
Digital indicator light 12 RGB-LEDs
|
24 logical signal inputs
|
-
|
Wide range power supply
|
FE
|
|
|
Indicator lights 6 LEDs
|
6 logical signal inputs
|
-
|
24V DC
|
FE
|
|
|
Digital indicator light 16 RGB-LEDs
|
32 logical signal inputs
|
-
|
Wide range power supply
|
FE
|
|
|
Indicator lights 6 LEDs
|
6 logical signal inputs
|
-
|
24V DC
|
FE
|
|
|
Digital indicator light 6 RGB-LEDs
|
12 logical signal inputs
|
-
|
Wide range power supply
|
FE
|
|
|
Indicator lights 8 LEDs
|
8 logical signal inputs
|
-
|
24V DC
|
FE
|
|
|
Digital indicator light 8 RGB-LEDs
|
16 logical signal inputs
|
-
|
Wide range power supply
|
FE
|
|
|
Digital bus indicator light 12 RGB-LEDs
|
-
|
-
|
Wide range power supply
|
FE
|
|
|
Digital bus indicator light 16 RGB-LEDs
|
-
|
-
|
Wide range power supply
|
FE
|
|
|
Digital bus indicator light 6 RGB-LEDs
|
-
|
-
|
Wide range power supply
|
FE
|
|
|
Digital bus indicator light 8 RGB-LEDs
|
-
|
-
|
Wide range power supply
|
FE
|
|
|
Single-phase digital power meter with integrated current transformer
|
1x AC voltage and 1x AC current
|
Analog standard signal output and semiconductor output
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers, RS485 and Ethernet interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with external clip-on current transformers, RS485 and Ethernet interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
Obsolescent model
|
|
Three-phase digital power meter with integrated current transformers and RS485-interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Single-phase digital power meter with integrated current transformer, analog standard signal output and VarioControl interface
|
1x AC voltage and 1x AC current
|
Analog standard signal output
|
Wide range power supply
|
GVD
|
|
|
Single-phase digital power meter with external clip-on current transformer, analog standard signal output and VarioControl interface
|
1x AC voltage and 1x AC current
|
Analog standard signal output
|
Wide range power supply
|
GVD
|
Obsolescent model
|
|
Three-phase digital power meter with external clip-on current transformers, RS485-interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers, RS485 and PROFIBUS interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers, RS485 and PROFINET interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers, RS485 and PROFIBUS interface, separate supply terminals
|
3x AC voltage and 3x AC current
|
-
|
Wide range power supply
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers, RS485 and PROFINET interface, separate supply terminals
|
3x AC voltage and 3x AC current
|
-
|
Wide range power supply
|
GT
|
Obsolescent model
|
|
Three-phase analog power meter with analog standard signal output
|
3x AC voltage and 3x AC current
|
Analog standard signal output and semiconductor output
|
Wide range power supply
|
GA
|
|
|
Three-phase analog power meter with analog standard signal output
|
3x AC voltage and 3x AC current
|
Analog standard signal output
|
Wide range power supply
|
GT
|
|
|
Three-phase digital power meter with external clip-on current transformers, RS485 and PROFIBUS interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with external clip-on current transformers, RS485 and PROFINET interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with external clip-on current transformers, RS485 and PROFIBUS interface, separate supply terminals
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with external clip-on current transformers, RS485 and PROFINET interface, separate supply terminals
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers and analog signal output
|
3x AC voltage and 3x AC current
|
Analog standard signal output
|
Wide range power supply
|
GT
|
|
|
Three-phase digital power meter with external clip-on current transformers and analog sigan output
|
3x AC voltage and 3x AC current
|
Analog standard signal output
|
Wide range power supply
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers for front panel mounting, TFT display
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
FE
|
|
|
Three-phase digital power meter with integrated current transformers for front panel mounting, TFT display and RS485 interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
FE
|
|
|
Three-phase digital power meter with integrated current transformers for front panel mounting, TFT display and solid-state outputs
|
3x AC voltage and 3x AC current
|
Solid-state outputs
|
Supply via measurement voltage
|
FE
|
|
|
Three-phase digital power meter with integrated current transformers for front panel mounting, TFT display, RS485 interface and solid-state outputs
|
3x AC voltage and 3x AC current
|
Solid-state outputs
|
Supply via measurement voltage
|
FE
|
|
|
Three-phase digital power meter with integrated current transformers, analog signal output, relay output and RS485 interface
|
3x AC voltage and 3x AC current
|
Analog standard signal output and relay output
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers, analog signal output, solid-state output and RS485 interface
|
3x AC voltage and 3x AC current
|
Analog standard signal output and solid state output
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with integrated current transformers, analog standard signal output, relay and semiconductor output and VarioControl interface
|
3x AC voltage and 3x AC current
|
Analog standard signal output, relay and solid-state output
|
Wide range power supply
|
GVF
|
|
|
Three-phase digital power meter with external clip-on current transformers, analog standard signal output, relay and semiconductor output and VarioControl interface
|
3x AC voltage and 3x AC current
|
Analog standard signal output, relay and solid-state output
|
Wide range power supply
|
GVF
|
|
|
Three-phase digital power meter with integrated current transformers, analog signal output, relay output and RS485 interface
|
3x AC voltage and 3x AC current
|
4xAnalog standard signal output and 2xrelay output
|
Supply via measurement voltage
|
GA
|
News
|
|
Three-phase digital power meter with neutral line measurement, external clip-on current transformers, analog signal output, solid-state output and RS485 interface
|
3x AC voltage and 3x AC current
|
4xAnalog standard signal output and 2xsolid-state output
|
Supply via measurement voltage
|
GT
|
News
|
|
Three-phase digital power meter with neutral line measurement, integrated current transformers, analog signal output, solid-state output and RS485 interface
|
3x AC voltage and 3x AC current
|
4xAnalog standard signal output and 2xsolid-state output
|
Supply via measurement voltage
|
GT
|
|
|
Three-phase digital power meter with external clip-on current transformers, analog signal output, relay output and RS485 interface
|
3x AC voltage and 3x AC current
|
4xAnalog standard signal output and 2xrelay output
|
Supply via measurement voltage
|
GA
|
|
|
Three-phase digital power meter with integrated current transformers for front panel mounting, TFT display and PROFIBUS interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
FE
|
|
|
Three-phase digital power meter with integrated current transformers for front panel mounting, TFT display and PROFINET interface
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
FE
|
No longer available
|
|
Load monitor for cos-phi and undervoltage
|
3x AC voltage and 1x AC current
|
Relay
|
Wide range power supply
|
GS
|
News
|
|
Load monitor for cos-phi and undervoltage
|
3x AC voltage and 1x AC current
|
Relay
|
Wide range power supply
|
GVC
|
|
|
Analog limit switch with touch code switch
|
Analog standard signal input
|
Relay
|
Wide range power supply
|
GS
|
|
|
Digital limit switch with VarioControl interface
|
Analog standard signal input
|
Relay
|
Wide range power supply
|
GVD
|
|
|
TFT display and control units with RS485 interface
|
-
|
-
|
Wide range power supply
|
FE
|
News
|
|
RS485-Modbus data logger with TFT display, USB, Ethernet and RS485 interface,
|
-
|
-
|
Wide range power supply
|
FE
|
|
|
Minimum-maximum evaluator
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Analog multiplier
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Measuring transducer for potentiometer signals
|
Potentiometer
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog PT100 transducer for 2- and 3-wire sensors
|
PT100 (2- and 3-wire)
|
Analog standard signal output
|
Wide range power supply
|
GL
|
|
|
Analog PT100 transducer for 2- and 3 wire sensors in 6.2 mm design
|
PT100 (2- and 3-wire)
|
Analog standard signal output
|
24V DC
|
GX
|
|
|
Analog PT100 transducer for 2-, 3- and 4-wire sensors
|
PT100 (2-, 3- and 4-wire)
|
Analog standard signal output
|
Wide range power supply
|
GL
|
|
|
Analog PT100 transducer for 4-wire sensors
|
PT100 (4-wire)
|
Analog standard signal output
|
24V DC
|
GL
|
|
|
Analog PT100 transducer for 4 wire sensors in 6.2 mm design
|
PT100 (4-wire)
|
Analog standard signal output
|
24V DC
|
GX
|
|
|
Digital temperature to bus converter for many popular sensors in 6.2 mm design
|
RTD, PT, NI, Thermoelements, mV
|
-
|
24V DC
|
GX
|
|
|
Digital temperature measuring transducer for many common sensors with analog standard signal outputs and VarioControl interface
|
RTD, PT, NI, Thermoelements, mV
|
Analog standard signal output
|
Wide range power supply
|
GVD
|
News
|
|
Four channel digital temperature to bus converter for many popular sensors
|
RTD, PT, NI, Thermoelements, mV
|
-
|
Wide range power supply
|
|
|
|
Analog PT100 isolation transmitter for 3-wire sensors
|
PT100 (3-wire)
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
ST
|
|
|
Interface converter RS485 to Ethernet
|
-
|
-
|
Wide range power supply
|
GT
|
|
|
Photovoltaic surplus controller with one load relay
|
3x AC voltage and 3x AC current
|
1 load relay, 1 alarm relay
|
Supply via measurement voltage
|
GT
|
|
|
Photovoltaic surplus controller with analog standard signal output for stepless load control
|
3x AC voltage and 3x AC current
|
Analog standard signal output
|
Supply via measurement voltage
|
GT
|
|
|
Photovoltaic surplus controller for connection to my-PV AC-Elwa-E
|
3x AC voltage and 3x AC current
|
-
|
Supply via measurement voltage
|
GT
|
|
|
Photovoltaic surplus controller with thee load relay
|
3x AC voltage and 3x AC current
|
3 load relay, 1 alarm relay
|
Supply via measurement voltage
|
GT
|
|
|
Photovoltaic surplus controller with three load relays in combination with heating element, flow heater set, circulation pump and thermostat
|
3x AC voltage and 3x AC current
|
3 load relays, 1 fault signal relay
|
Supply via measuring voltage
|
GT
|
|
|
Set of Photovoltaic surplus controller and heater rod
|
3x AC voltage and 3x AC current
|
3 load relay, 1 alarm relay
|
Supply via measurement voltage
|
GT
|
News
|
|
Photovoltaic surplus controller with three load relays, analog and digital outputs, temperature measurement, Ethernet, USB, RS485, WiFi and display
|
3x AC voltage, 3x AC current, digital, analog, temperature
|
3 load relay, 1 alarm relay, digital, analog
|
Supply via measurement voltage
|
GT
|
|
|
Redundancy analyzer
|
Analog standard signal inputs
|
Analog standard signal output
|
Wide range power supply
|
GVF
|
|
|
Analog limit switch with transmitter supply and touch code switch
|
Analog standard signal input
|
Relay
|
Wide range power supply
|
GS
|
|
|
Digital summing amplifier
|
Analog standard signal inputs
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Digital multifunctional power supply isolating amplifier with DIP switch for signal selection (HART transparent)
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Analog 1:1 isolation amplifier for standard current signals in 6.2 mm design
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
24V DC
|
GX
|
|
|
Analog 1:1 supply isolation amplifier for standard current signals in 6.2 mm design
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
Wide range power supply
|
GL
|
|
|
Analog 1:1 supply isolation amplifier for standard current signals
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
Wide range power supply
|
GVB
|
|
|
Analog 1:1 supply isolation amplifier for standard current signals
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
24V DC
|
GL
|
|
|
Analog 1:1 supply isolation amplifier for standard current signals
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
24V DC
|
GVB
|
|
|
Multifunctional supply isolating analog amplifier
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Digital multifunctional power supply isolating amplifier with DIP switch for signal selection
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Fast analog bipolar supply isolation amplifier for standard analog signals
|
Analog standard signal input with transmitter supply
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
EX digital supply isolation amplifier
|
Analog standard signal input with transmitter supply (Exi)
|
Analog standard signal output
|
Wide range power supply
|
GVD
|
|
|
DC voltage converter
|
12V DC
|
24V DC
|
-
|
GL
|
|
|
Power supply for two-wire transmitter 1-channel
|
-
|
24V DC
|
Wide range power supply
|
GS
|
|
|
Power supply for two-wire transmitter 2-channel
|
-
|
2x 24V DC
|
Wide range power supply
|
GS
|
|
|
AC isolation amplifier 3-channel with sine wave output
|
AC currents
|
Sinus voltage
|
Wide range power supply
|
GL
|
|
|
Standard signal setpoint generator with touch code switch
|
-
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
AC isolation amplifier 3-channel with clip-on current transformers and sine wave output
|
AC currents
|
Sinus voltage
|
Wide range power supply
|
WG
|
|
|
AC isolation amplifier 3-channel with clip-on current transformers, switchable input measuring range and sine wave output
|
AC currents
|
Sinus voltage
|
Wide range power supply
|
WG
|
|
|
AC current transformer transmitter with clip-on current transformer (100 A)
|
AC currents
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
-
|
|
|
TRMS AC current transformer transmitter with clip-on current transformer (100 A)
|
AC currents
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
-
|
|
|
AC current transformer transmitter with clip-on current transformer (200 A)
|
AC currents
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
-
|
|
|
TRMS AC current transformer transmitter with clip-on current transformer (200 A)
|
AC currents
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
-
|
|
|
AC current transformer transmitter with clip-on current transformer (50 A)
|
AC currents
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
-
|
|
|
TRMS AC current transformer transmitter with clip-on current transformer (50 A)
|
AC currents
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
-
|
|
|
Analog 1:1 isolation amplifier for standard voltage signals in 6.2 mm design
|
Analog standard signal input
|
Analog standard signal output
|
24V DC
|
GX
|
|
|
Analog 1:1 isolation amplifier for standard voltage nd special input voltages. Suitable for battery applications.
|
Analog standard signal input
|
Analog standard signal output
|
12 and 24V DC
|
GVB
|
|
|
Analog multiplier isolation amplifier in 6.2 mm design
|
Analog standard signal input
|
2x Analog standard signal output
|
24V DC
|
GX
|
|
|
Analog 1:1 isolation amplifier for standard current signals in 6.2 mm design
|
Analog standard signal input
|
Analog standard signal output
|
24V DC
|
GX
|
|
|
Analog customized analog isolation amplifier
|
Analog standard signal input
|
Analog standard signal output
|
24V DC or 230V AC
|
EV
|
|
|
Analog customized analog isolation amplifier
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog customized analog isolation amplifier
|
Analog standard signal input
|
Analog standard signal output
|
24V DC
|
ST
|
|
|
Analog 1:1 isolation amplifier for standard current signals
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GL
|
|
|
Analog 1:1 isolation amplifier for standard current signals
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GVB
|
|
|
Analog 1:1 isolation amplifier for standard current signals
|
Analog standard signal input
|
Analog standard signal output
|
24V DC
|
GL
|
|
|
Analog 1:1 isolation amplifier for standard current signals Suitable for battery applications.
|
Analog standard signal input
|
Analog standard signal output
|
12 and 24V DC
|
GVB
|
|
|
Analog multifunction isolation amplifier in 6.2 mm design. Signal switching via DIP switch.
|
Analog standard signal input
|
Analog standard signal output
|
24V DC
|
GX
|
|
|
Analog multifunction isolation amplifier. Signal switching via clamps and trimmers.
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GL
|
|
|
Analog multifunction isolation amplifier. Signal switching via clamps.
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog cd analog isolation amplifier for special signals
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog multifunction isolation amplifier with simulation function. Signal switching via clamps and trimmers.
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GL
|
|
|
Analog multifunction isolation amplifier with simulation function, remote activation, feedback contact and transmitter supply
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog multifunction isolation amplifier. Signal switching via DIP switch.
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GL
|
|
|
|
Analog standard signal input
|
High current output
|
Wide range power supply
|
GVF
|
|
|
Digital multifunctional isolating amplifier with DIP switch for signal selection
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Digital multifunction isolation amplifier with analog standard signal output, sink output and VarioControl interface
|
Analog standard signal input
|
Analog standard signal output, sink output
|
Wide range power supply
|
GVD
|
|
|
Analog one-channel 1:1 isolation amplifier for standard current signals
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog two-channel 1:1 isolation amplifier for standard current signals
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Digital multifunction isolation amplifier with 2 analog standard signal outputs and VarioControl interface
|
Analog standard signal input
|
2x Analog standard signal output
|
Wide range power supply
|
GVD
|
|
|
Analog multiplier isolation amplifier (2 outputs)
|
Analog standard signal input
|
2x Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog multiplier isolation amplifier (2 outputs)
|
Analog standard signal input
|
2x Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Analog multiplier isolation amplifier (4 outputs)
|
Analog standard signal input
|
4x Analog standard signal output
|
Wide range power supply
|
GVF
|
|
|
Analog AC isolation amplifier for AC currents with integrated current transformers
|
AC currents
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Analog AC isolation amplifier for AC mains voltages
|
AC voltages
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Digital AC isolation amplifier for AC currents with integrated current transformers
|
AC currents
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Digital AC isolation amplifier for AC currents with integrated current transformers and external clip-onnt transformers
|
AC currents
|
Analog standard signal output, relay
|
Wide range power supply
|
GVD
|
|
|
Digital AC isolation amplifier for AC mains voltages
|
AC voltages
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
Fast analog bipolar isolation amplifier for standard analog signals
|
Analog standard signal input
|
Analog standard signal output
|
Wide range power supply
|
GS
|
|
|
One-channel analog 1:1 isolator converter for standard current signals
|
Analog standard signal input
|
Analog standard signal output
|
-
|
GS
|
|
|
One-channel analog 1:1 isolator converter for standard current signals for pcb mounting
|
Analog standard signal input
|
Analog standard signal output
|
-
|
MO
|
|
|
One-channel analog 1:1 isolator converter for standard current signals in plug-in module technology
|
Analog standard signal input
|
Analog standard signal output
|
-
|
ST
|
|
|
Two-channel analog 1:1 isolator converter for standard current signals
|
2x Analog standard signal input
|
2x Analog standard signal output
|
-
|
GS
|
|
|
Analog 1A AC isolating converter with standard analog signal output
|
AC currents
|
Analog standard signal output
|
-
|
GVD
|
|
|
Analog 5A AC isolating converter with standard analog signal output
|
AC currents
|
Analog standard signal output
|
-
|
GVD
|
|
|
One-channel analog 1:1 isolator converter for standard current signals
|
Analog standard signal input
|
Analog standard signal output
|
-
|
GM
|
|
|
One-channel analog 1:1 isolator converter for standard current signals in plug-in module technology
|
Analog standard signal input
|
Analog standard signal output
|
-
|
ST
|
|
|
Analog 1:1 isolation transmitter
|
Analog standard signal input
|
Analog standard signal output (Current sink)
|
Supply via output (transmitter supply voltage)
|
GM
|
News
|
|
Digital three-phase voltage monitor
|
3x AC-voltage
|
Relay
|
Supply via measurement voltage
|
GT
|
|
|
Snap-on display and adjustment module with RS485 bus interface
|
-
|
-
|
via basic device
|
-
|
|
|
Snap-on display and adjustment module
|
-
|
-
|
via basic device
|
-
|
Obsolescent model
|
|
USB parameterization adapter for AD-UART interface and RS485 bus
|
-
|
-
|
via USB
|
-
|
|
|
USB parameterization adapter for AD-UART interface and RS485 bus
|
-
|
-
|
via USB
|
-
|
|
|
Digital multifunctional measurement transducer for analog standard and temperature signals, analog standard signal outputs and VarioControl interface
|
Analog standard signal input, transmitter supply, potentiometer, RTD, PT, NI, thermocouples, mV
|
Analog standard signal output
|
Wide range power supply
|
GVD
|
|
|
Digital multifunctional measurement transducer for analog standard and temperature signals, 2 relays, analog standard signal outputs and VarioControl interface
|
Analog standard signal input, transmitter supply, potentiometer, RTD, PT, NI, thermocouples, mV
|
Analog standard signal output, 2x relay
|
Wide range power supply
|
GVD
|
Obsolescent model
|
|
Digital multifunction measurement transducer for analog standard signals, with LCD display and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output
|
Wide range power supply
|
GF
|
Obsolescent model
|
|
Digital multifunction measurement transducer for analog standard signals, with LCD display, 2 relays and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 2x relay
|
Wide range power supply
|
GF
|
Obsolescent model
|
|
Digital multifunction measurement transducer for analog standard signals, with LCD display, 4 relays and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 4x relay
|
Wide range power supply
|
GF
|
|
|
Digital multifunction measurement transducer for analog standard signals, with LCD display and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output
|
Wide range power supply
|
GVF
|
|
|
Digital multifunction measurement transducer for analog standard signals, with LCD display, 2 relays and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 2x relay
|
Wide range power supply
|
GVF
|
|
|
Digital multifunction measurement transducer for analog standard signals, with LCD display, 4 relays and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 4x relay
|
Wide range power supply
|
GVF
|
|
|
Digital multifunction measurement transducer for analog standard signalsband analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Digital multifunction measurement transducer for analog standard signalsband analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 2x relay
|
Wide range power supply
|
GVF
|
|
|
Digital multifunction measurement transducer for analog standard signalsband analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 4x relay
|
Wide range power supply
|
GVF
|
|
|
Digital multifunction measurement transducer for front-panel mount for analog standard signals, with LCD display and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output
|
Wide range power supply
|
FE
|
|
|
Digital multifunction measurement transducer for front-panel mount for analog standard signals, with LCD display, 2 relays and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 2x relay
|
Wide range power supply
|
FE
|
|
|
Digital multifunction measurement transducer for front-panel mount for analog standard signals, with LCD display, 4 relays and analog standard signal outputs
|
Analog standard signal input, transmitter supply, potentiometer
|
Analog standard signal output, 4x relay
|
Wide range power supply
|
FE
|
|
|
Digital multifunctional measurement transducer for temperature signals, with LCD display and analog standard signal outputs
|
RTD, PT, NI, Thermoelements, mV
|
Analog standard signal output
|
Wide range power supply
|
GVF
|
|
|
Digital multifunctional measurement transducer for temperature signals, with LCD display, 2 relaysg standard signal outputs
|
RTD, PT, NI, Thermoelements, mV
|
Analog standard signal output, 2x relay
|
Wide range power supply
|
GVF
|
|
|
Digital multifunctional measurement transducer for temperature signals, with LCD display, 4 relays and analog standard signal outputs
|
RTD, PT, NI, Thermoelements, mV
|
Analog standard signal output, 4x relay
|
Wide range power supply
|
GVF
|
|
|
Digital multifunctional measurement transducer for temperature signals and analog standard signal outputs
|
RTD, PT, NI, Thermoelements, mV
|
Analog standard signal output
|
Wide range power supply
|
GVC
|
|
|
Digital multifunctional measurement transducer for temperature signals, 2 relaysg standard signal outputs
|
RTD, PT, NI, Thermoelements, mV
|
Analog standard signal output, 2x relay
|
Wide range power supply
|
GVF
|
|
|
Digital multifunctional measurement transducer for temperature signals, 4 relays and analog standard signal outputs
|
RTD, PT, NI, Thermoelements, mV
|
Analog standard signal output, 4x relay
|
Wide range power supply
|
GVF
|
News
|
|
Eight-channel data logger with analog standard signal input, TFT-display, RS485 bus and USB- and Ethernet interface
|
8x analog standard signal input
|
-
|
Wide range power supply
|
FE
|
|
|
Single-channel data logger with analog standard signal input and SD card
|
Analog standard signal input
|
-
|
Wide range power supply
|
FE
|
|
|
Four-channel data logger with analog standard signal input and SD card
|
4x analog standard signal input
|
-
|
Wide range power supply
|
FE
|
|
|
Eight-channel data logger with analog standard signal input and SD card
|
8x analog standard signal input
|
-
|
Wide range power supply
|
FE
|
|
|
Single-channel display unit with analog standard signal input
|
Analog standard signal input
|
-
|
Wide range power supply
|
FE
|
|
|
Four-channel display unit with analog standard signal inputs
|
4x analog standard signal input
|
-
|
Wide range power supply
|
FE
|
|
|
Eight-channel display unit with analog standard signal inputs
|
8x analog standard signal input
|
-
|
Wide range power supply
|
FE
|