AD-TV 561 GS

Description

The isolation amplified AD-TV 561 GS converts sinus wave alternating voltages to analogue, optionally according to the effective values, output signals in up to three independent channels. With the measuring principle of real effective value measuring, distorted alternating signals can also be accurately captured. Input, output, the supply voltage and the channels amongst each other are galvanically isolated from each other. The output signals are independent of the connected load up to a maximum value.

AD-TV 561 GS

Application

Capturing, galvanic isolation, conversion and amplification of alternating voltages in analogue signals. Optional effective value conversion, adaptation and amplification of output signals of voltage converters.

Business data

Order number
AD-TV 561 GS
Identifiers
EClass 27210120
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Downloads
Data sheet pdf en-tv561gs.pdf (151 kB)
Safety instructions pdf ad-safety-instructions.pdf (43 kB)

Technical specifications

Input
Mess. range min/max 0 ... 30 V AC / 0 ... 600 V AC 1)
Input frequency 50 ... 60 Hz, Sinus Grundschwingung
Input resistance 1 kOhm / V input voltage
Output current
Max. output range 0/4 ... 20 mA 1)
Max. burden 500 Ohm
Output voltage
Max. output range 0 .. 10 V 1)
Min. burden 1 kOhm
Transmission behaviour
Linearity error 0,3 % from the final value at fundamental
Rise time (10...90%) 700 ms
Temperature influence +/- 100 ppm/K
Ripple current Max. 50 µAss
Ripple voltage Max. 100 mVss
Supply
Supply voltage 20 ... 253 V DC / 50 ... 253 V AC
Max. power consumption 1 W / 2,1 VA
Housing
Manner of fastening DIN rail 35mm (EN 50022)
Type of protection IP 20
Connector cross section Max. 2,5 mm²
Bolting torque screw terminals 0,5 Nm
Weight Ca. 110 g
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 60 °C
EMC
Product family standard EN 61326-1
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Pollution degree 2
Safety measurement EN 61010-2-030
Measurement category CAT III
Galvanic isolation, test voltages
Input/output 4 kV (1 min)
Input/power-supply 4 kV (1 min)
Output/power-supply 3 kV (1 min)
1)Values must be advised by order
2) During electromagnetic disturbance minor changes in output signal are possible.

Block and wiring diagram

AD-TV 561 GS

Dimensions

AD-TV 561 GS

CAD / CAE Daten

CAD model is not yet available for this product.

The CAD product overview can be found at: adamczewski.partcommunity.com