AD-LU 320 GVD

Description

The digital power measuring transducer AD-LU 320 GVD measures all quantities of the power-network (current, voltage, energy, harmonics, phase angle, active power, reactive power, apparent power) and converts these measuring values onto two freely scalable analogue outputs. The unit is therefore optimal suitable for integration in energy management systems. For measuring of high voltages or high currents, external transformers can be connected in series at any time. All measuring ranges and outputs can be freely parameterized. This can be carried out via the optional operating modul AD-VarioControl or via the programming software AD-Studio. The LEDs at the front signals the operating condition. The compact type of construction and the high performance ability with simultaneous low energy consumption allows usage in almost any application.

AD-LU 320 GVD

Application

Typical usage in plant, machines or energy management systems for balancing and determination of energy distribution.

Specific characteristics

  • Measurement of a phase
  • Measuring quantities: active power, reactive power, apparent power, currents and voltages, frequency, power factor, harmonics (active power), energy metering
  • current and voltage output
  • Counters for active power (consuption and infeed), reactive power (inductive and capacitive) and apparent power
  • 23 mm narrow housing with detachable terminal clamp
  • Operating module AD-VarioControl as an accessory

Business data

Order number
AD-LU 320 GVD
Accessory (optional)
Operating module AD-VarioControl
USB programming adapter AD-VarioPass
Configuration software AD-Studio
Identifiers
EClass 27210124
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Downloads
Data sheet pdf en-lu320gvd.pdf (288 kB)
Operation manual VarioControl pdf man-variocontrol-ad-en.pdf (1 MB)
Tender text zip lu320gvd.zip (11 kB)
Safety instructions pdf ad-safety-instructions.pdf (43 kB)

Technical specifications

Input current
Measuring ranges 0 ... 1 A AC; 0 ... 5 A AC
Max. measurable harmonic 40
Input voltage
Measuring range 10 ... 253 V AC
Input resistance > 1 MOhm
Output current
Output range 0/4 ... 20 mA
Max. load 400 Ohm
Resolution 11 Bit
Residual ripple 25 µAss
Output voltage
Output range 0/2 ... 10 V
Min. load 10 kOhm
Resolution 11 Bit
Residual ripple 20 mVss
Supply
Voltage range AC 50 ... 253 V AC, 50/60 Hz
Nominal voltage AC / DC 230 V AC / 24 V DC
Voltage range DC 20 ... 253 V DC
Power consumption AC / DC 3,4 VA / 1,8 W
Power consumption with operating module AC / DC 3,6 VA / 2,0 W
Transmission behaviour
Basic accuracy < 0,5 % (class 0.5)
Temperature influence 80 ppm/K
Response time < 0,5 s (0...90 %, 100...10 %)
Housing
Dimensions (WxHxD) 23x110x134mm
With operating module (bxhxt) 23x110x138 mm
Type of protection IP 20
Connection method Detachable terminal clamp
Terminals, wire cross section 2,5 mm² flex wire / 4 mm² one wire
Bolting torque terminals 0,5 Nm
Skinning length 6 mm
Weight ~ 150 g
Manner of fastening 35 mm DIN rail 35mm
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard EN 61326-1 1)
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
1) During checking, slight signal deviations are possible.
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Pollution degree 2
Safety measurement EN 61010-2-030
Measurement category CAT III
Galvanic isolation, test voltages
Input to analog outputs / power-supply 4 kV, 50 Hz (1 min.)
Power-supply to analog out 3 kV, 50 Hz (1 min.)
Protection circuits
Input Electrical surge protection
Power supply Protection against over-temperature, over-voltage and over-current
Analog outputs Electrical surge protection

Block and wiring diagram

AD-LU 320 GVD

Dimensions

AD-LU 320 GVD

Circuit examples

AD-LU 320 GVD

CAD / CAE Daten

Under "Generate CAD", select the desired CAD model for this product.
For this purpose, registration with our CAD database "PARTcommunity" is required.
The complete CAD product overview can be found at: adamczewski.partcommunity.com

AD-LU 320 GVD

Display and operating elements

On: LED for operating display in green
on - normal operation
flashing - Signal failure, signal outside range limits

Modbus Communication

The optional AD-VarioConnect operating module has an RS-485 interface. The data is transferred via the Modbus RTU protocol, the AD-VarioConnect operating module represents a Modbus slave. Communication takes place according to the master-slave procedure and starts with a request from the master, e.g. from a PLC or a PC. Each bus participant must have a unique address. If a slave detects that its address has been addressed by the master, the slave always sends an answer. The slaves never communicate with each other. They are also not able to start a communication with the master.
The Modbus master can read out the individual registers of the AD-LU 320 GVD via the addresses.
The default standard data format is 19200,e,8,1 with slave address 1. These settings can be changed via the AD-VarioConnect operating module.

Start address Number of registers Name Unit Data type read write

 Measured values:
40202 1 digital output A 3 1 1
40203 1 digital output B 3 1 1
40204 1 digital output A LED 3 1 1
40205 1 digital output B LED 3 1 1
40501 2 active power total kW 7 1 0
40503 2 active power total L1 kW 7 1 0
40509 2 total reactive power kvar 7 1 0
40511 2 reactive power L1 kvar 7 1 0
40517 2 total apparent power kVA 7 1 0
40519 2 apparent power L1 kVA 7 1 0
40525 2 total power factor 7 1 0
40527 2 power factor in L1 7 1 0
40533 2 total active fundamental power kW 7 1 0
40535 2 active fundamental power L1 kW 7 1 0
40541 2 total active harmonic power kW 7 1 0
40543 2 active harmonic power L1 kW 7 1 0
40549 2 voltage L1 / N V 7 1 0
40555 2 current N line (calculated) A 7 1 0
40557 2 current in L1 A 7 1 0
40563 2 voltage peak L1 V 7 1 0
40569 2 current peak L1 A 7 1 0
40575 2 frequency Hz 7 1 0
40585 2 phase angle Psi L1 ° 7 1 0
40801 2 output current mA 7 1 0
40803 2 output voltage V 7 1 0

Counter:
44003 2 counter kWh - consuption kWh 5 1 1
44005 2 counter kWh - infeed kWh 5 1 1
44007 2 counter kVarh - inductiv kVarh 5 1 1
44009 2 counter kVarh - capacitiv kVarh 5 1 1
44011 2 counter kVAh - apparent energy kVAh 5 1 1


Legend of the datatypes:
U08: 1 S08: 2 U16: 3 S16: 4 U32: 5 S32: 6 float: 7