AD-MV 550 GVD

Description

The digital temperature measuring transformer AD-MV 550 GVD serves the galvanic separation and transformation of resistance transmitter or thermocouples to an impressed output signal (i.e. 0-20 mA). All measuring ranges and outputs can be freely parameterized. This can be carried out via the optional control panel AD-VarioControl or via the programming software AD-Studio. Due to its current-sinking output, transmitter signals can also be galvanic separated or transformed. The wide range power pack covers all supply regions.

AD-MV 550 GVD

Specific characteristics

  • Resistance thermometer inputs, types Pt/Ni 100, Pt/Ni 500, Pt/Ni 1000
  • Thermocouples inputs, types J, T, K, E, N, S, R, B, C or inputs a mV/T-characteristic curve. Selectable internal or external reference junction
  • A bipolar mV-Voltage input. Free linearizing curves possible.
  • bipolar current or voltage output
  • current sink output
  • Operating module as an accessory
  • 23 mm narrow housing with detachable terminal clamp

Business data

Order number
Temperature Measuring Converter AD-MV 550 GVD
Accessory (optional)
Operating module AD-VarioControl
USB programming adapter AD-VarioPass
Configuration software AD-Studio
Identifiers
EClass 27210129
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Technical specifications

Resistance thermometer inputs Pt100, Pt500, Pt1000 to DIN EN 60751
Measuring range -200 ... +850 °C
Connection method 2-, 3- oder 4-wire system
Accuracy 0,5 K
Smallest measuring spans 20 K
Max line resistance 1) 10 Ohm/cable
Sensor supply
Pt100 1 mA
Pt500, Pt1000 210 µA
1) With 2-conductor the line resistance comes as an offset into the measurement.
Resistance thermometer inputs Ni100, Ni500, Ni1000 to DIN EN 43760
Measuring range -60 ... +230 °C
Connection method 2-, 3- oder 4-wire system
Accuracy 0,5 K
Smallest measuring spans 20 K
Max line resistance 1) 10 Ohm/cable
Sensor supply
Ni100 1 mA
Ni500, Ni1000 210 µA
1) With 2-conductor the line resistance comes as an offset into the measurement.
Thermocouples
Comparative place:
Internal Measurement with LM35 in the device connecting terminals
External Cold junction temperatureselectable by parameters
Measuring range type J -200 ... +1200 °C
To DIN EN 60584:
Measuring range type T -200 ... +400 °C
Measuring range type K -200 ... +1360 °C
Measuring range type E -200 ... +1000 °C
Measuring range type N -200 ... +1300 °C
Measuring range type S -40 ... +1760 °C
Measuring range type R -40 ... +1760 °C
Measuring range type B +400 ... +1800 °C
After standard ASTM E988:
Measuring range type C 0 ... +2320 °C
Smallest measuring spans 100 K
Voltage inputs
Measuring range -18 ... +18 mV
-36 ... +36 mV
-72 ... +72 mV
-144 ... +144 mV
Output current
Max. output range -21,5 ... 21,5 mA DC
Max. burden 400 Ohm
Residual ripple 40 µAss
Output voltage
Max. output range -10,5 ... 10,5 V DC
Min. burden 10 kOhm
Residual ripple 30 mVss
Current sink output
Current sink 0/4 ... 20 mA DC
Max. voltage to be applied 35 V DC
Resolution
Input 16 bit
Output 12 bit
Transmission behaviour
Linearity error 0,2 % of full scale
Rise time 600 ms (output auf 90 %)
Temperature influence +/- 100 ppm/K of full scale
Supply
Voltage range AC 50 ... 253 V AC, 50/60 Hz
Nominal voltage AC 230 V AC
Voltage range DC 20 ... 253 V DC
Nominal voltage DC 24 V DC
Power consumption AC / DC 2,4 VA / 1,2 W
Housing
Dimensions (WxHxD) 23x110x134 mm
With operating module (bxhxt) 23x110x138 mm
Type of protection IP 20
Connection method Detachable terminal clamp
Terminals, wire cross section 2,5 mm² flex wire / 4 mm² one wire
Bolting torque terminals 0,5 Nm
Weight ~ 150 g
Manner of fastening 35 mm DIN rail 35mm
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard 1) EN 61326-1
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
1)During electromagnetic disturbance minor changes in output signal are possible.
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Pollution degree 2
Galvanic isolation, test voltages
Input/output 2,5 kV (1 min)
Signal/auxiliary voltage 4 kV (1 min)

Block and wiring diagram

AD-MV 550 GVD

Dimensions

AD-MV 550 GVD

We only use technically necessary cookies to improve the user-friendliness of our site.
Cookies for analysis and marketing purposes are not used!
You can find further information in our privacy policy.