Description

The measuring value transformer AD-MV 500 GL transforms the measuring signal emitted from a resistance thermometer (Pt 100) to an impressed output signal (i.e. 4...20 mA, 0...10 V o.a.). The output characteristic is outputted temperature-linear. When using the 3- or 4-conductor switching, the conductor resistances are compensated up to 100 Ohm. With 2-conductor switching, a subsequent zero balance and full balance is necessary. The measuring process can be set via easily accessible DIP switches at the front. The analogue output signal is always galvanic separated from the supply voltage and also from the input. Input and output data must be stated in clear text when ordering. With the input, the temperature measuring range must be stated and with the output, as alternative, current or voltage output can be selected.

AD-MV 500 GL

Application

Temperature measuring with Pt100 temperature transmitter for continuous transformation of temperature variables to analogue signals.

Specific characteristics

  • Pt100 input
  • current or voltage output
  • type of connection selectable over DIP switch on the front-panel
  • galvanic isolation between input, output and power-supply
  • Trimmer for fine adjustment on the front-panel

Business data

Order number
AD-MV 500 GL
Identifiers
EClass 27210129
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Technical specifications

Pt100 input
Max. measuring range -200 ... 800 °C1)
Connection method 2, 3 or 4-wire
Output current
Output range 0 ... 20 mA, 4 ... 20 mA1)
Max. burden 400 Ohm
Residual ripple 50 µAss
Output voltage
Output range 0 ... 10 V, 2 ... 10 V 1)
Min. burden 1 kOhm
Residual ripple 70 mVss
Supply
Voltage range AC 50 ... 253 V AC, 50/60 Hz
Nominal voltage AC 230 VAC
Voltage range DC 20 ... 253 V DC
Nominal voltage DC 24 V DC
Power consumption AC / DC 2 VA / 1W
Transmission behaviour
Accuracy < 0,2 %
Temperature influence 100 ppm/K
Response time ~ 50 ms
Housing
Dimensions (WxHxD) 18x78x103 mm
Type of protection IP 20
Connection method Screw clamp
Terminals, wire cross section 2,5 mm² flex wire / 4 mm² one wire
Bolting torque terminals 0,5 Nm
Weight ~ 100 g
Manner of fastening 35 mm DIN rail 35mm
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard EN 61326-1 2)
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Pollution degree 2
Galvanic isolation, test voltages
Input / output 3,75 kV (1 min.)
Signal / supply unit 4 kV (1 min.)
Protection circuits
Input Electrical surge protection
Output Electrical surge protection
Power supply Electrical surge and reverse current protection
1) Specify signal range in plain text when ordering.
2) During electromagnetic disturbance minor changes in output signal are possible.