AD-TV 310 GS

Description

The separation amplifier of type family AD-TV 310 serves the galvanic separation, conversion and amplification of unipolar signal sizes. Input, output and the supply voltage are galvanically separated from each other. The output signal is independent of the connected load up to a maximum value.

AD-TV 310 GS

Application

Recording, galvanic 3-way separation, conversion and amplification of unipolar measuring sizes (voltage or current).

Business data

Order number
AD-TV 310 GS
Identifiers
EClass 27210120
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Downloads
Data sheet pdf en-tv310.pdf (191 kB)
Safety instructions pdf ad-safety-instructions.pdf (43 kB)

Technical specifications

Input current
Measuring range 0...1 mA ; 0...200 mA 1)
Input resistance 25 Ohm
Input voltage
Measuring range 0...100 mV ; 0...250 V 1)
Input resistance 100 kOhm (10 kOhm / Volt)
Output current
Output range 0...1 mA ; 0...20 mA 1)
Max. burden 500 Ohm
Max. residual ripple 40 µAss
Output voltage
Output range 0...1 V ; 0...10 V 1)
Min. burden 1 kOhm
Max. residual ripple 20 mVss
Supply
Voltage range AC 50 ... 253 V AC, 50/60 Hz
Nominal voltage AC 230 V AC
Voltage range DC 20 ... 253 V DC
Nominal voltage DC 24 V DC
Input power AC/DC 3,5 VA / 1,7 W
Transmission behaviour
Basic accuracy < 0,2 %
Temperature influence 100 ppm/K
Frequency range 0...10 Hz (-3dB)
Housing
Dimensions (WxHxD) 23x78x103 mm
Type of protection IP 20
Connection method Screw clamp
Terminals, wire cross section 2,5 mm² flex wire / 4 mm² one wire
Bolting torque terminals 0,5 Nm
Weight ~ 100 g
Manner of fastening 35 mm DIN rail 35mm
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard EN 61326-1 2)
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Pollution degree 2
Galvanic isolation, test voltages
Input / output 3,75 kV, 50 Hz (1 min.)
Signal / supply unit 3,3 kV, 50 Hz (1 min.)
Protection circuits
Input Electrical surge protection
Output Electrical surge protection
Power supply Protection against overvoltage
reverse polarity
1) Values must be adviced by order.
2) During checking, slight signal deviations are possible.

Block and wiring diagram

AD-TV 310 GS

Dimensions

AD-TV 310 GS

CAD / CAE Daten

CAD model is not yet available for this product.

The CAD product overview can be found at: adamczewski.partcommunity.com

Cookie settings