AD-VC 3B GVF

Description

The digital multi-function measuring transformer of series VarioCheck AD-VC3B GVF are freely programmable digital measuring transformer with two analogue outputs and up to 4 limiting value relays. Extensive standard equipment and additional options solve almost all imaginable tasks of a modern evaluation. The input of all characteristics is carried out via the configuration software „AD-Studio“. VarioCheck AD-VC3B fulfils all tasks of a universal and secure measuring value recording through integral function modules such as limiting value messages, freely adjustable hysteresis, selectable relay functions, time-delayed switching, automatic or manual simulation modus, free linearizing curves and a wide range of supply voltage.

AD-VC 3B GVF

Specific characteristics

  • Bipolar voltage/current inputs
  • Supply of 2-/3-wire transmitter
  • Potentiometer input
  • Current and voltage output, differently scalable and can be utilised simultaneously
  • Zoom function, expanded scale, linearizing, inverse modus
  • Monitoring of the measuring signal with up to 4 freely adjustable limiting values
  • Non-volatile saving of all set parameter
  • Pluggable and codable terminal strips
  • Parameter configuration via optional PC setup program "AD-Studio"

Business data

Order number
AD-VC 3B GVC-R0 Without relay
AD-VC 3B GVF-R2 Two relays
AD-VC 3B GVF-R4 Four relays
Identifiers
EClass 27210107
Customs tariff number / country of origin 8543 70 90 / Deutschland

Information

Downloads
Data sheet pdf en-vc3b.pdf (349 kB)
Safety instructions pdf ad-safety-instructions.pdf (43 kB)

Technical specifications

Input current
Measuring range -20 ... + 20 mA
Accuracy 5 µA
Input resistance 60 Ohm
Voltage input 10V
Measuring range -10 ... + 10 V
Accuracy 2,5 mV
Input resistance 1 MOhm
Voltage input 1V
Measuring range -1 ... + 1 V
Accuracy 250 µV
Input resistance > 1 MOhm
Potentiometer input
Connection method 3-wire system
Max. Resistance 100 Ohm ... 100 kOhm
Transmitter supply
Off-load voltage 24,5 V
Voltage at 20mA 19,5 V
Current limit ~ 25 mA
Output current
Max. output range 0 ... 20,4 mA
Accuracy ~ 20 µA
Max. burden 500 Ohm
Residual ripple 20 µAss
Output voltage
Max. output range 0 ... 10,2 V
Accuracy ~ 10 mV
Min. burden 5 kOhm
Residual ripple 10 mVss
Resolution
Input 13 bit
Output 10 bit
Relay outputs A...D
Contacts GVF-R2 / GVF-R4 2 changeover contact / 4 changeover contact
Max. AC-breaking capacity 250 V AC, 2 A AC, 50Hz
Max. DC-breaking capacity 35 V DC, 2 A DC
Switching operations
Mechanical 107
AC: 230V / 2A, cos(phi)=1 6 * 105
AC: 230V / 2A, cos(phi)=0,4 2 * 105
DC: 24V / 1A 2 * 105
DC: 24V / 1A 2 * 105
Transmission behaviour
Linearity error 0,2 % of full scale
Rise time 100 ms (output auf 90 %)
Temperature influence +/- 100 ppm/K of full scale
Supply
Supply voltage 20 ... 253 V DC / 50 ... 253 V AC
Max. power consumption 2,6 W / 5 VAC
Housing
Manner of fastening DIN rail 35mm (EN 50022)
Type of protection IP 20
Connector cross section Max. 2,5 mm²
Weight ~ 200 g
Environmental conditions
Ambient temperature -10 ... 60 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard EN 61326-1
Discharge static electricity, ESD IEC 61000-4-2
Electromagnetic fields 1) IEC 61000-4-3
Fast transients, burst IEC 61000-4-4
Impulse voltage, surge IEC 61000-4-5
Conducted HF-Signals 1) IEC 61000-4-6
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
1)During electromagnetic disturbance minor changes in output signal are possible.
Galvanic isolation, test voltages
Input/output 2,5 kV (1 min)
Signal/auxiliary voltage 4 kV (1 min)

Block and wiring diagram

AD-VC 3B GVF

Dimensions

AD-VC 3B GVF

CAD / CAE Daten

CAD model is not yet available for this product.

The CAD product overview can be found at: adamczewski.partcommunity.com

Cookie settings
made with ♡ by andres.media