AD-TV 204 EV S-422

Description

The separation amplifier AD-TV 204 EV-S422 serves the galvanic separation of amplification, conversion or adjustment of analogue measuring signals. The slide-in card can contain up to 4 completely independent channels. With all channels input, output and supply voltage are galvanically separated. The channels are also completely insulated amongst each other. At each channel, input signal type and output signal type can be freely selected. A spindle trimmer is located at the front for direct adjustment. Due to the narrow construction (4 TE) up to 84 channels can be integrated in one standard module carrier.

AD-TV 204 EV S-422

Application

Galvanic separation, adjustment, amplification and conversion of analogue measuring signals in up to 4 independent channels.

Business data

Order number
AD-TV 204 EV S-422

Information

Downloads
Safety instructions pdf ad-safety-instructions.pdf (43 kB)

Technical specifications

Input
Measuring range current 0 ...20 mA; 4 ... 20 mA1)
Input resistances 50 Ohm
Measuring range voltage 0 ... 10 V, 2 ... 10 V1)
Input resistances 100 kOhm
Output
Output range current 0 ... 20 mA; 4 ... 20 mA1)
Max. burden 500 Ohm
Output range voltage 0 ... 10 V; 2 ... 10 V1)
Min. burden 500 Ohm
Residual ripple < 50 mVss
1)switchable and adjustable per channel; others on request
Transmission behaviour
Basic accuracy < 0,3 %
Temperature influence < 100 ppm/K
Supply
Supply voltage 20 ... 253 V DC / 50 ... 253 V AC
Nominal voltage 24 V DC / 230 V AC
Power consumption 5,4 W / 11 VA
Type of construction
Manner of fastening 19-Europakarte 4TE
Type of protection IP 00
Weight Ca. 160 g
Environmental conditions
Ambient temperature -10 ... 50 °C
Storage and transport -10 ... 70 °C (no condensation)
EMC
Product family standard EN 61326-1 2)
Emitted interference EN 55011, CISPR11 Cl. B, Gr. 1
2) During electromagnetic disturbance minor changes in output signal are possible.
Electrical safety requirements
Product family standard EN 61010-1
Overvoltage category II
Pollution degree 2
Galvanic isolation, test voltages
Input/output 0,5 kV RMS (1 min.)
Channel/channel 0,5 kV RMS (1 Min.)
Signal/auxiliary voltage 3 kV RMS (1 min.)
Protective systems
Input/output Electrical surge protection
Power supply Electrical surge and reverse current protection

Block and wiring diagram

AD-TV 204 EV S-422

Dimensions

AD-TV 204 EV S-422

CAD / CAE Daten

CAD model is not yet available for this product.

The CAD product overview can be found at: adamczewski.partcommunity.com

Cookie settings
made with ♡ by andres.media